Electrothermal validation
Each check compares a RunMat result with an independent reference: a closed-form solution, a manufactured solution or a published benchmark. The tests listed under a check run on every change and in the evidence report; receipts record a public study run with its build, commit and mesh. The validation methodology explains how checks are built and how tolerances are set, and Status summarizes every family.
Steady
Two-way Joule heating of a bar
Problem. A bar with resistivity carries a fixed current with its ends held at and its sides insulated: = 3 S/m, = 0.004 /K, = 1 W/m/K, = 34.64 A on a unit cube, Tet10 with 2, 4 and 8 cells.
Reference. The temperature rise solves with ; closed form with , and power .
Compared. Nodal temperature; Joule power against terminal power and against .
Tolerance. At least three coupling sweeps; temperature error falls at second order; terminal power equals the Joule integral within 1e-8; power within 0.5 % of .
Result. Passed (1 test) in the evidence run of 2026-11-08. Largest temperature error 2.21, 0.575 and 0.150 K at 2, 4 and 8 cells, against a 59.95 K peak rise; Joule power 461.47, 462.88 and 463.35 W against 463.52 W.
Tests: two_way_joule_heating_matches_the_closed_form_bar.
Joule heating of a slab, one way
Problem. A slab of constant conductivity dissipates 12 W, which drives a steady thermal solve on the same mesh; Tet4 and Tet10.
Reference. The quadratic temperature profile of uniform heat generation, and 12 W at the terminals, in the transfer and at the thermal boundary.
Compared. Terminal, transferred and boundary power; nodal temperature.
Tolerance. Power within 1e-8 W; Tet10 temperature within 1e-8; Tet4 interior error below 0.35 of the coarse mesh after one refinement.
Result. Passed (2 tests) in the evidence run of 2026-11-08.
Tests: retained_conduction_drives_independent_quadratic_thermal_patch_and_power, tet4_refinement_and_voltage_sign_gauge_preserve_independent_heat_and_power.