Heat transfer validation
Each check compares a RunMat result with an independent reference: a closed-form solution, a manufactured solution or a published benchmark. The tests listed under a check run on every change and in the evidence report; receipts record a public study run with its build, commit and mesh. The validation methodology explains how checks are built and how tolerances are set, and Status summarizes every family.
Steady
Two-layer slab in series
Problem. A slab of two half-meter layers with k = 1 and 4 W/(m·K), held at fixed temperatures on its outer faces; Tet4.
Reference. One-dimensional series thermal resistance: piecewise-linear temperature and a uniform flux of 160 W/m².
Compared. Nodal temperature; element heat flux; dependence on the order in which the materials are authored.
Tolerance. Temperature within 1e-7 K; flux within 1e-6 W/m²; reordering the materials changes the result by less than 1e-10.
Result. Passed (1 test) in the evidence run of 2026-11-08.
Tests: two_material_slab_matches_series_resistance_and_authored_order_is_invariant.
Bar between two fixed temperatures
Problem. A bar held at a hot and a cold end temperature with insulated sides.
Reference. Fourier's law through the bar, .
Compared. Heat entering and leaving through the prescribed ends; net prescribed reaction.
Tolerance. Heat flow within relative 1e-8 of ; the net reaction cancels to 1e-8 of it.
Result. Passed (1 test) in the evidence run of 2026-11-08.
Tests: bar_between_two_fixed_temperatures_reports_its_closed_form_heat_flow.
Tet10 conduction patch test
Problem. A single quadratic tetrahedron under a linear temperature field.
Reference. Constant-gradient patch: conductivity rows sum to zero, the gradient is exactly (2, 3, −1), the flux is , and the integrated capacity equals .
Compared. Conductivity row sums, temperature gradient, heat flux, integrated capacity.
Tolerance. Relative 1e-12.
Result. Passed (1 test) in the evidence run of 2026-11-08.
Tests: canonical_tet10_thermal_matrices_pass_constant_patch_and_capacity_integral.
Radiating bar
Problem. A 1 m steel bar ( = 45 W/m/K) takes 1000 W/m² on one end and radiates from the other ( = 0.8, 300 K surroundings). The public example is radiating-bar.fea; the test runs the same bar on Tet4 and Tet10 meshes.
Reference. Gray-surface radiation at the radiating end, , and conduction across the bar.
Compared. Temperatures at both ends and along the bar; applied and radiated power.
Tolerance. Nodal temperature within relative 1e-8 of the closed form; applied power equals radiated power.
Result. Passed (1 test) in the evidence run of 2026-11-08. RunMat gives 416.6790 K at the radiating end and 438.9013 K at the heated end; the closed form gives the same values to 1e-12. 10 W applied, 10 W radiated.
Tests: radiating_bar_matches_the_gray_surface_closed_form_and_balances_power.
Slab radiating from a fixed hot face
Problem. A slab held at 400 K on one face radiates from the opposite face; Tet4 and Tet10.
Reference. The scalar gray-surface equilibrium of the slab, solved independently by bisection.
Compared. Nodal temperature, gradient and flux; radiated power against conducted power.
Tolerance. Temperature, gradient and flux within relative 1e-8; radiated power equals the prescribed-face power within 1e-8.
Result. Passed (1 test) in the evidence run of 2026-11-08.
Tests: fixed_hot_slab_matches_independent_gray_surface_scalar_equilibrium.
Transient
Uniformly heated insulated body
Problem. An insulated body with uniform volumetric heating, integrated with backward Euler on Tet4 and Tet10 meshes.
Reference. The continuum temperature history of the heated body and its stored-energy law: storage rate equals applied power.
Compared. Temperature at every step; applied, stored and boundary power.
Tolerance. Discrete solution within 1e-8; error equals the backward-Euler term within 1e-8 and falls at first order (ratio below 0.56 per halving); storage rate equals applied power within 1e-8; energy residual below 1e-10.
Result. Passed (1 test) in the evidence run of 2026-11-08.
Tests: uniform_ramp_heating_has_continuum_backward_euler_time_convergence.
Manufactured radiative cooling
Problem. A body cooling by surface radiation under a manufactured solution, on Tet4 and Tet10 meshes with 8, 16 and 32 backward-Euler steps.
Reference. The manufactured temperature history and its gradient, flux and stored heat.
Compared. Temperature, gradient, heat flux and storage; power closure.
Tolerance. Every error falls by more than 1.8× per halving of the step (first order); power closes.
Result. Passed (1 test) in the evidence run of 2026-11-08.
Tests: manufactured_continuum_cooling_retains_first_order_backward_euler_and_power_closure.