Values, units and expressions
A design value is a number with its unit, a reference to another value, or an expression of them. The compiler checks the dimension of every value against where it is used: a sketch coordinate takes a length, a revolve angle takes an angle, a resistor value takes a resistance. Values are stored in SI units, so 80 mm, 8 cm and 0.08 m are the same length.
Value forms
| Form | Example | Meaning |
|---|---|---|
| Quantity | 80 mm, 30 deg, 10 kohm | A number and its unit. A space separates them. |
| Number | 2.5, 4 | A dimensionless value, such as a count or a ratio. |
| String | "PL-100", "R0402-10K" | Text: part numbers, file paths, names that are not plain words. |
| Word | cut, third_angle, power | A choice from a fixed set, such as mode = cut. |
| List | [0 mm, 40 mm], [feature.round, feature.slot] | An ordered list; points and vectors are lists. |
| Record | { body = feature.body.body, part_number = "PL-100" } | Named fields. |
| Reference | input.width, let.half, feature.body.face.end, net.GND | Another item's value or entity, by kind and name. |
| Expression | input.width / 2 + 5 mm, -input.offset | Arithmetic on values. |
| Tolerance | 10 mm ± 0.1 mm, 10 mm ± [0.02 mm, 0 mm], 10 kohm ± 1 % | A nominal value with symmetric or [plus, minus] bounds. |
| Function call | camBaseRadius(lift = input.lift, rise = 120 deg) | A value computed by a .m function. See MATLAB functions in design values. |
Inputs
An input is a parameter of the design. Configurations, runs and sweeps set inputs without editing the rest of the file.
runmat 0.7
std 1
part spacer {
input outer : length = 12 mm
input bore : length = { default = 6.4 mm, minimum = 3 mm, maximum = input.outer }
input height : length = 8 mm
sketch ring on origin.xy {
rim = circle(center = [0 mm, 0 mm], radius = input.outer / 2)
hole = circle(center = [0 mm, 0 mm], radius = input.bore / 2)
}
feature body = extrude(profile = sketch.ring, distance = input.height)
output spacer = { body = feature.body.body, part_number = "SP-12" }
}input <name> : <kind> = <default>declares an input. The kind is required; the default is optional.- The record form
{ default = …, minimum = …, maximum = … }adds bounds. A value outside them is an error at the input. A bound may itself be an input, asmaximum = input.outeris above. - A reference to an input is
input.<name>.
Let values
let <name> = <value> names a value inside one file. Other statements read it as let.<name>, or by its bare name inside an expression. Lets are evaluated in dependency order, so a let may use another let written below it. A cycle (let a = let.b, let b = let.a) is an error.
runmat 0.7
std 1
part tab {
input width : length = 40 mm
let half = input.width / 2
let height : length = let.half + 5 mm
sketch s on origin.xy {
l1 = line(start = [0 mm, 0 mm], end = [input.width, 0 mm])
l2 = line(start = [input.width, 0 mm], end = [input.width, let.height])
l3 = line(start = [input.width, let.height], end = [0 mm, let.height])
l4 = line(start = [0 mm, let.height], end = [0 mm, 0 mm])
}
feature body = extrude(profile = sketch.s, distance = 3 mm)
output tab = { body = feature.body.body }
}A let may state its kind (let height : length = …); the checker then compares the value's dimension with it.
Expressions
| Operator | Meaning | Dimension rule |
|---|---|---|
a + b, a - b | sum, difference | a and b have the same dimension |
a * b | product | dimensions multiply: length * length is an area |
a / b | quotient | dimensions divide: length / length is dimensionless |
-a | negation | unchanged |
( … ) | grouping | unchanged |
Multiplication and division bind tighter than addition and subtraction, and ± binds loosest: 20 mm + 2 * 5 mm ± 0.1 mm is 30 mm with a tolerance of 0.1 mm.
Tolerances
A toleranced value carries its nominal and its bounds. Geometry and solvers use the nominal; checks read the bounds. In a .part, the size and location statements attach toleranced values to faces as PMI, which drawings and STEP exports carry (see Outputs, regions and published values). In a .circuit, a component's toleranced value sets the spread a tolerance study samples (see Simulation sections and measures).
| Written | Nominal | Bounds |
|---|---|---|
25 mm ± 0.1 mm | 25 mm | 24.9 mm to 25.1 mm |
10 mm ± [0.02 mm, 0 mm] | 10 mm | 10 mm to 10.02 mm |
10 kohm ± 1 % | 10 kΩ | 9.9 kΩ to 10.1 kΩ |
Units
Mechanical files
.part, .assembly and .drawing values take these kinds and units:
Kind (as written after :) | Units |
|---|---|
length, distance | m, cm, mm, um (also µm), in, ft |
area | m^2, mm^2 |
angle | deg, rad |
mass | kg, gram |
real, dimensionless, count, integer | a bare number |
A bare number where a length is expected is an error: write 5 mm, not 5. Imperial lengths read as written: 40 ft, 5.5 in, and a feet-and-inches length is a sum, 8 ft + 1.125 in. Board coordinates in a .circuit.layout are the exception: a bare number there is millimetres.
Electrical files
.circuit and .circuit.layout values take SI units with the SI prefixes T, G, M, k, m, u (also µ), n, p and f:
| Quantity | Unit | Examples |
|---|---|---|
| Resistance | ohm (also Ohm, Ω) | 10 kohm, 4.7 Mohm, 0.5 mohm |
| Capacitance | F | 100 nF, 10 uF |
| Inductance | H | 2.2 uH |
| Voltage | V | 3.3 V, 22.2 V |
| Current | A | 20 A, 1 mA |
| Frequency | Hz | 48 kHz |
| Time | s | 5 ns, 14 us |
| Power, energy, charge | W, J, C | 62.5 mW |
| Conductance | S | 1 mS |
| Length | m | 0.2 mm; board lengths also take mil |
| Temperature | K, degC | 25 degC |
| Tolerance | % | ± 1 % |
The circuit printer writes quantities in SI units (10000 ohm), so a file reads back bit for bit; any of the forms above reads in.
Strings and words