RunMat
  • Pricing
RunMat
GitHub
GitHub
Sign inTry in browser
DesktopRuntimePhysicsCADAdministrationAgent

Get RunMat updates

New releases, guides and examples.

Product+
  • Runtime
  • GPU
  • Parallel
  • Compile
  • Interop and MEX
  • Simulation
  • MCAD
  • ECAD
  • Enterprise
  • AI integrations
  • Pricing
  • Download
Math+
  • Signal processing
  • Linear algebra
  • Statistics
  • Curve fitting
  • Differential equations
  • Control systems
  • Optimization
  • Finance
  • Data and tables
  • Plotting
Physics+
  • Simulation overview
  • Structural
  • Thermal
  • Electromagnetic
  • Joule heating
  • Thermal stress
  • Acoustics
  • Fluid flow
  • Conjugate heat transfer
  • Fluid–structure
  • What is FEA
Industries+
  • Aerospace
  • Automotive and transportation
  • Defense
  • Electronics and semiconductors
  • Energy
  • Industrial machinery
  • Life sciences
  • Quantitative finance
Learn+
  • Guides
  • Docs
  • Function reference
  • Language reference
  • Migration guide
  • Changelog
  • MATLAB Online
  • MATLAB AI agent
  • For students
Compare+
  • RunMat vs MATLAB
  • RunMat vs Ansys
  • RunMat vs SOLIDWORKS
  • RunMat vs Altium
  • RunMat vs Cadence
  • RunMat vs COMSOL
  • RunMat vs Python
  • RunMat vs Julia
  • RunMat vs Physics AI
  • RunMat vs Octave
  • Benchmarks
  • MATLAB alternatives
  • All comparisons
Company+
  • About
  • Blog
  • Contact
  • Source code↗
  • License
  • Privacy
  • Terms

Product

  • Runtime
  • GPU
  • Parallel
  • Compile
  • Interop and MEX
  • Simulation
  • MCAD
  • ECAD
  • Enterprise
  • AI integrations
  • Pricing
  • Download

Math

  • Signal processing
  • Linear algebra
  • Statistics
  • Curve fitting
  • Differential equations
  • Control systems
  • Optimization
  • Finance
  • Data and tables
  • Plotting

Physics

  • Simulation overview
  • Structural
  • Thermal
  • Electromagnetic
  • Joule heating
  • Thermal stress
  • Acoustics
  • Fluid flow
  • Conjugate heat transfer
  • Fluid–structure
  • What is FEA

Industries

  • Aerospace
  • Automotive and transportation
  • Defense
  • Electronics and semiconductors
  • Energy
  • Industrial machinery
  • Life sciences
  • Quantitative finance

Learn

  • Guides
  • Docs
  • Function reference
  • Language reference
  • Migration guide
  • Changelog
  • MATLAB Online
  • MATLAB AI agent
  • For students

Compare

  • RunMat vs MATLAB
  • RunMat vs Ansys
  • RunMat vs SOLIDWORKS
  • RunMat vs Altium
  • RunMat vs Cadence
  • RunMat vs COMSOL
  • RunMat vs Python
  • RunMat vs Julia
  • RunMat vs Physics AI
  • RunMat vs Octave
  • Benchmarks
  • MATLAB alternatives
  • All comparisons

Company

  • About
  • Blog
  • Contact
  • Source code↗
  • License
  • Privacy
  • Terms
GitHubXLinkedIn

© Dystr, Inc. · RunMat v0.7.1, Nov 17, 2026

RunMat® is a registered trademark of Dystr, Inc. MATLAB® is a registered trademark of The MathWorks, Inc. RunMat is not affiliated with, endorsed by, or sponsored by The MathWorks, Inc.

/
    • Overview
    • Structural
    • Thermal
    • Electromagnetic
    • Trace impedance
    • Acoustics
    • Fluid flow
    • Thermal stress
    • Joule heating
    • Conjugate heat transfer
    • Fluid–structure
Docs>Physics>Physics

Conjugate heat transfer

Conjugate heat transfer (CHT) solves the flow and temperature of a coolant together with conduction in the part it cools. Fluid and solid keep their own materials and equations; a declared interface carries temperature and heat flux across the wetted surface, so the film coefficient comes from the flow instead of a guess.

runmat run executes steady conjugate heat transfer from a .fea study. The flow is the canonical cell-centred finite-volume solution of the fluid flow analysis on the fluid regions. One nodal energy equation then spans every fluid and solid element: Galerkin conduction in both, conservative advection by the solved flow in the fluid, and streamline-upwind stabilization where the flow dominates conduction. Fluid and solid are coupled inside that single linear system, so the interface balance holds to the solver tolerance at every node.

What equations define conjugate heat transfer?

The solid satisfies

ρscs∂Ts∂t−∇⋅(ks∇Ts)=Qs,\rho_s c_s\frac{\partial T_s}{\partial t} -\nabla\cdot(k_s\nabla T_s)=Q_s,ρs​cs​∂t∂Ts​​−∇⋅(ks​∇Ts​)=Qs​,

while the fluid energy equation includes advection,

ρfcf(∂Tf∂t+u⋅∇Tf)−∇⋅(kf∇Tf)=Qf.\rho_f c_f\left(\frac{\partial T_f}{\partial t} +\mathbf u\cdot\nabla T_f\right)-\nabla\cdot(k_f\nabla T_f)=Q_f.ρf​cf​(∂t∂Tf​​+u⋅∇Tf​)−∇⋅(kf​∇Tf​)=Qf​.

At a perfect interface,

Tf=Ts,−kf∇Tf⋅nf=ks∇Ts⋅ns=qn.T_f=T_s,\qquad -k_f\nabla T_f\cdot\mathbf n_f =k_s\nabla T_s\cdot\mathbf n_s=q_n.Tf​=Ts​,−kf​∇Tf​⋅nf​=ks​∇Ts​⋅ns​=qn​.

A finite conductance hch_chc​ (or contact resistance R=1/hcR = 1/h_cR=1/hc​) allows a jump, qn=hc(Ts−Tf)q_n=h_c(T_s-T_f)qn​=hc​(Ts​−Tf​).

How does RunMat discretize the coupled energy equation?

  • The solved finite-volume face fluxes are lifted into every fluid tetrahedron as its lowest-order Raviart–Thomas velocity. That velocity reproduces each face flux, is exactly divergence-free in a mass-conserving cell and has continuous normal flux between cells, so the summed advection rows equal the enthalpy carried through the boundary: transport neither creates nor loses energy.
  • A perfect interface shares the conformal interface nodes. A conductance or resistance gives each interface node a second, fluid-side temperature joined to the solid side by hc∫(Ts−Tf)Ni dAh_c\int(T_s-T_f)N_i\,dAhc​∫(Ts​−Tf​)Ni​dA, which removes from one side exactly the heat it adds to the other.
  • Flow entering the fluid must carry an authored inlet temperature; outflow leaves with its own temperature; walls without a thermal law are adiabatic.

Which conjugate heat-transfer procedures are defined?

ProcedureContractExecution
conjugate_heat_transfer steadySteady flow and steady temperature in fluid and solidRuns from runmat run
conjugate_heat_transfer transientSteady flow advecting a backward-Euler temperature march from the authored initial temperatureRuns from runmat run
conjugate_heat_transfer nonlinearTemperature-dependent propertiesTyped contract; not yet executed

How do I declare a fluid–solid thermal interface?

model cooled_part {
    assign material.aluminum to geometry.cooler.region.solid
    assign material.water to geometry.cooler.region.fluid

    constraint wetted { fluid.no_slip_wall { target = geometry.cooler.region.fluid_wall } }
    interface wall_transfer {
        conjugate_heat_transfer.conductance {
            primary = geometry.cooler.region.solid_wall
            secondary = geometry.cooler.region.fluid_wall
            coefficient = 5000 W/m^2/K
        }
    }
}

study cooler {
    geometry = geometry.cooler
    mesh = mesh.cooler
    model = model.cooled_part
    analysis operating_point { conjugate_heat_transfer steady {} }
    output temperature = analysis.operating_point.field.node.temperature
    output velocity = analysis.operating_point.field.cell.fluid_velocity
}

Use conjugate_heat_transfer.perfect where the coolant wets bare metal, conductance for a coating and resistance for a gap pad. Primary and secondary are typed, visible roles; proximity never creates an interface automatically, and every face where a fluid meets a solid must belong to a declared interface. The fluid side of the wetted wall still needs its flow law, usually fluid.no_slip_wall.

What does a conjugate run publish?

  • field.node.temperature: the solved nodal temperature over fluid and solid. Where an interface carries a jump, the node value is the solid side; the fluid side is retained with the result.
  • field.cell.fluid_velocity, field.cell.fluid_pressure and the face volume flux of the fluid.
  • Evidence for every interface: the heat entering the fluid and the solid through it (equal and opposite), its relative imbalance and, for a finite conductance, the largest temperature jump and the residual of q=hcΔTq=h_c\Delta Tq=hc​ΔT.
  • Global energy closure: applied heat, convective losses, enthalpy carried out of the fluid and heat drawn at prescribed temperatures, with their relative imbalance.

Why is my predicted cooling wrong?

Check inlet flow and temperature, fluid properties, solid conductivity, interface law, contact area, boundary-layer resolution across the passage, heat-source power, and the reported energy closure. Laminar flow only: turbulent coolant is not modelled.

See heat transfer, fluid flow, interfaces, thermal loads, and current status.

On this page
  • What equations define conjugate heat transfer?
  • How does RunMat discretize the coupled energy equation?
  • Which conjugate heat-transfer procedures are defined?
  • How do I declare a fluid–solid thermal interface?
  • What does a conjugate run publish?
  • Why is my predicted cooling wrong?