Predict temperature and heat flow in your parts and assemblies

Check that a part stays under its temperature limit at full power and through its duty cycle. Import the STEP file, write the materials, heat sources and cooling in a short text file, and RunMat solves it.

Download RunMat
Temperature of the eight cells of battery module M01, from 301.066 K at the cold plate to 303.869 K at the cell tops, drawn inside the translucent CAD of the rest of the battery pack
Example: the eight prismatic cells of one module in an EV battery pack, each generating 20 W and cooled from below by the module’s cold plate. Colors show the temperature, up to 303.9 K (30.7 °C) at the cell tops.

RunMat works with you to set up your studies

Go from a CAD file to a complete, runnable study in minutes.

RunMat asks you guided questions to set up the study. It checks for missing heat sources, cooling and the rest of the simulation setup, so the study is ready before you run it.

You own the study file: run it, review it and check it into version control. Model anything from conduction in a simple heat sink to a liquid-cooled battery module with multiphysics.

How guided setup works

Simulation setup asking what to simulate for the bracket, with Strength or deformation under load selected

Studies are deterministic, typed documents

Guided setup writes and fills out a study document like the one shown here. The document is typed, with units, and static analysis underlines incorrect connections and definitions in red.

Studies are text files, so you can read, write, keep and rerun them at any time.

Read the input language

battery-module-cells.fea
material li_ion_cell {
mass_density = 2500 kg/m^3
thermal {
reference_temperature = 298.15 K
modulus_temperature_coefficient = 0 K^-1
expansion_coefficient = 0.00001 K^-1
conductivity = 20 W/m/K
specific_heat = 1000 J/kg/K
}
}
geometry module {
file = "./geometry/m01-cells.step"
units = mm
interfaces = shared
region cell_1 : solid { select name "M01 cell 1"; expect exactly_one }
region cell_2 : solid { select name "M01 cell 2"; expect exactly_one }
region cell_3 : solid { select name "M01 cell 3"; expect exactly_one }
region cell_4 : solid { select name "M01 cell 4"; expect exactly_one }
region cell_5 : solid { select name "M01 cell 5"; expect exactly_one }
region cell_6 : solid { select name "M01 cell 6"; expect exactly_one }
region cell_7 : solid { select name "M01 cell 7"; expect exactly_one }
region cell_8 : solid { select name "M01 cell 8"; expect exactly_one }
region cell_bottoms : face { select name "M01 cell bottom"; expect one_or_more }
}
mesh module on geometry.module {
tetrahedra { order = linear; target_size = 12 mm; maximum_deviation = 0.2 mm }
}
model module_cooling {
thermal { reference_temperature = 298.15 K }
assign material.li_ion_cell to geometry.module.region.cell_1
assign material.li_ion_cell to geometry.module.region.cell_2
assign material.li_ion_cell to geometry.module.region.cell_3
assign material.li_ion_cell to geometry.module.region.cell_4
assign material.li_ion_cell to geometry.module.region.cell_5
assign material.li_ion_cell to geometry.module.region.cell_6
assign material.li_ion_cell to geometry.module.region.cell_7
assign material.li_ion_cell to geometry.module.region.cell_8
load cell_1_heat { heat_generation on geometry.module.region.cell_1 = 12383.9 W/m^3 }
load cell_2_heat { heat_generation on geometry.module.region.cell_2 = 12383.9 W/m^3 }
load cell_3_heat { heat_generation on geometry.module.region.cell_3 = 12383.9 W/m^3 }
load cell_4_heat { heat_generation on geometry.module.region.cell_4 = 12383.9 W/m^3 }
load cell_5_heat { heat_generation on geometry.module.region.cell_5 = 12383.9 W/m^3 }
load cell_6_heat { heat_generation on geometry.module.region.cell_6 = 12383.9 W/m^3 }
load cell_7_heat { heat_generation on geometry.module.region.cell_7 = 12383.9 W/m^3 }
load cell_8_heat { heat_generation on geometry.module.region.cell_8 = 12383.9 W/m^3 }
load cold_plate {
thermal.convection {
target = geometry.module.region.cell_bottoms
ambient_temperature = 298.15 K
coefficient = 403 W/m^2/K
}
}
}
study module_temperature {
geometry = geometry.module
mesh = mesh.module
model = model.module_cooling
analysis heat { thermal steady {} }
output temperature = analysis.heat.field.node.temperature
output heat_flux = analysis.heat.field.element.heat_flux
}

Run a simulation across your machines

The same study runs on every core of one computer, or spreads across several machines when the model is large or there are many cases to solve. On Professional, each person's three computers run together as a cluster, and larger clusters run under Enterprise.

Scale from local to clusterParallel computing

LaptopRemote serverLARGE CLUSTER

RunMat helps you answer temperature questions before you build hardware

Does it stay under its temperature limit?

Get the peak temperature and where it occurs at the operating power and cooling, checked against the limit for the cell, the component or a touch-safe surface and reported passed or failed.

How much cooling does it need?

Run film coefficients, coolant temperatures and heat-sink variants side by side in parallel, and find the least cooling that holds the peak under the limit.

How long until it reaches its limit?

Follow a power cycle, a warm-up or a cool-down over time, and get the time at which the hottest point reaches its limit.

Will the temperature warp or crack it?

Pass the temperature field to a thermal stress analysis on the same part and mesh, and get the stress and distortion it causes.

The following thermal simulation types are supported

Steady conduction: Temperature

Steady conduction

Operating temperature once the part reaches equilibrium with its heat sources and cooling.

Temperature of an aluminum heat spreader warming up from a 20 W pad, solved in RunMat

Transient conduction

Warm-up, cool-down and the response to a power cycle, stepped in time from an initial temperature.

Temperature of eight battery cells on a cold plate, from 301.1 K at the bottoms to 303.9 K at the tops, solved in RunMat

Internal heat generation

Heat generated inside battery cells, windings, dies and resistors, in W/m³ or from a component's total power.

Temperature falling along an aluminum pin fin from its 80 C base, solved in RunMat

Convection cooling

Air or coolant cooling as a film coefficient and an ambient temperature on the cooled faces, natural or forced, with its own ambient on each face.

Temperature of an aluminum radiator panel radiating 40 W to space, solved in RunMat

Radiation to the surroundings

Gray-surface radiation from a face to its surroundings, set by emissivity and surrounding temperature, on the same faces as convection.

Contact and interface conductance

Heat across bonded joints, thermal interface materials and bolted contacts, as perfect contact or a conductance or resistance on a declared interface.

Parabolic temperature along a stainless heater rod with both ends held at 20 C, solved in RunMat

Fixed and controlled temperatures

Faces held at a known temperature or a measured temperature history, such as a controlled cold plate, with the heat flow needed to hold them there.

Temperature in one cell of a finned heat sink with periodic sides, solved in RunMat

Periodic and repeating cells

One cell of a fin array, a lattice or a repeating sector, with periodic temperature, an imposed gradient or a heat-flow rate across it.

Model heat sources, cooling and materials

Define the heat sources, boundaries and materials of complex cases.

Heat sources

  • Heat generation in a volume, in W/m³
  • Heat flux on a face, in W/m²
  • A component's total power over its volume or face
  • Imposed temperature fields from test or another solver
  • Power cycles and measured histories, including from .m functions
  • Joule heat from an electrical analysis

Cooling and boundaries

  • Convection to air or coolant, with an ambient per face
  • Radiation to the surroundings
  • Fixed temperatures and measured temperature histories
  • Ambient temperature as a time signal
  • Insulated and adiabatic faces

Interfaces

  • Perfect contact and temperature ties between meshes
  • Contact conductance and contact resistance
  • Thermal interface materials as a layer or a boundary law
  • Periodic, sector and fixed-jump temperature pairs

Materials and results

  • Conductivity, density and specific heat
  • Initial temperatures for transient runs
  • Temperature, gradient, heat flux and heat rate
  • Energy balance on every run

RunMat can be used directly by Claude Code, Codex and other MCP clients

Connect RunMat to Claude Code, Codex or another MCP client, and the AI tool you already use sets up and runs the same studies from your CAD file. Its agent writes and edits the .fea study, RunMat checks and solves it, and the results come back to the agent and appear in RunMat Desktop.

Connect your AI toolRead the agent docs

FAQ

01How do I know a thermal result is right?

Check that the heat generated equals the heat leaving through the boundaries, and refine the mesh until the peak temperature stops changing. Every run records its energy balance: the battery module generates 160 W and convects 160 W out, with a residual below 1e-12 W, and its cell-top temperature is within 0.006 K of a one-dimensional slab estimate.

Heat transfer validation

02How do I model contact between two parts?

Declare an interface between the faces: perfect contact, or a thermal conductance or contact resistance. Touching parts exchange heat only through an interface you declare.

Thermal contact

03Does RunMat model thermal radiation?

Yes. Radiation from a surface to its surroundings is a boundary condition with an emissivity and a surrounding temperature, and it can sit on the same faces as convection.

Thermal loads

04Can RunMat model airflow from a fan?

Air cooling is a convection boundary: a film coefficient and an air temperature on the cooled faces, with a higher coefficient for forced air. To solve the coolant flow and the solid together, use conjugate heat transfer.

Conjugate heat transfer

05Why does my steady model fail with a singular system?

A steady part needs at least one fixed temperature or convection boundary to set its temperature level. RunMat reports the missing reference instead of inventing one.

Singular thermal solves

06Can I enter temperatures in Celsius?

Yes. 25 degC and 298.15 K are the same temperature in a study, and RunMat converts between them when it checks units.

07Can an AI model write a thermal study?

Yes. A study is plain text with units on every value, so an AI coding agent such as Claude Code or Codex can write it from a description of the part, its heat sources and its cooling, and runmat check reports any mistake with its line before anything is meshed.

Simulation in RunMat

Run your first thermal study

Download RunMat

Read the thermal reference